The core technology of purified water equipment adopts single-stage or double-stage reverse osmosis, EDI and other latest processes to design targeted high-quality pure water treatment processes in a targeted manner to meet the purified or distilled water of pharmaceuticals, hospitals and laboratory diagnostic reagents. The preparation of water requirements, the entire system is made of SUS304L or 316L all stainless steel material combination, and before the water point must be equipped with ultraviolet, ozone generator disinfection device or can also be pasteurized.
Model | ZYGMPRO-I-150/250/500/1000/1500/2000L | ||||
Feed Water | TDS<500ppm, water pressure 1.0-5.0kg/cm2 Working Temperature25℃ | ||||
Power Supply | AC220V/50HZ or AC380V/50HZ | ||||
Capacity(L) | 250L/H | 500L/H | 1000L/H | 1500L/H | 2000L/H |
Power(KW) | 1.1-1.5 | 1.5-2.5 | 2.5-3.5 | 2.5-3.5 | 2.5-3.5 |
Water Quality(μs/cm) | Conductivity 5<μs/cm,TOC≤0.5mg/L,Microorganism<100cfu/ml | ||||
Body Size(mm) | 1400*800*1600 | 1500*800*1600 | 1800*800*1800 | ||
Floor Space | About 8㎡ | About 10-12㎡ | About 12-15㎡ | ||
Weight (kg) | <300KG | <600KG | <1000KG | ||
Application | Biopharmaceutical water, medical device water, reagent liquid water, hospital dialysis water, drinking liquid water, medical purified water | ||||
Sterile Tank | 250L | 500L | 1000L | 1500L | 2000L |
Water Inlet Pipe Size | DN20 | DN20-25 | DN25-32 | DN25-32 | DN32-40 |
Parameter:
1. Feed water: Meet the sanitary standards for drinking water (pressure 0.2-0.5MPa); conductivity ≤ 500μs/cm; total hardness <300PPM
2. Power supply : AC380/220V 50HZ, three-phase five-wire, reliable grounding
3.Temperature: 5-40 °C; Atmospheric pressure: 700Kpa-1060Kpa; Relative humidity: ≤ 80%
4. Desalination rate ≥99%
5.The maximum operating pressure: ≤ 1.5Mpa
6.Installation site requirements: Smooth ground with a waterproof layer, a smooth floor drainage
7. Avoid direct sunlight, strong magnetic field interference environment
Working flow:
Common configuration:
(1) Pretreatment + Primary Reverse Osmosis + Secondary Reverse Osmosis + Sterilizer + Circulatory System
(2) Pretreatment + Primary Reverse Osmosis + EDI Equipment + Sterilization Device + Circulatory System
(3) Pretreatment + Primary Reverse Osmosis + Secondary Reverse Osmosis + EDI Equipment + Sterilization Device + Circulatory System