Water production | 250-10000L/H (Customized is available.) |
Working pressure | 0.2-0.4 Mpa |
Water temperature | 5-40 ℃ |
RO membrane DN | 0.0001-0.001um |
Ion removal rate | ≥99%; |
Endotoxin, bacterial removal rate | ≥99%; |
Recovery | ≥75%; |
Effluent conductivity | ≤ 15us / cm (source water quality TDS <200ppm) |
No. | Model | Water yield (L/H) | Voltage/Power (V/Kw) | Body Size (L*W*H mm) | Water Tank (L/Material) |
1 | ZYRO-250 | 250 | 380/2.5 | 1400*700*1640 | 250/stainless steel/PE |
2 | ZYRO-500 | 500 | 380/3.5 | 1400*700*1640 | 500/stainless steel/PE |
3 | ZYRO-750 | 750 | 380/4.5 | 1400*700*1640 | 750/stainless steel/PE |
4 | ZYRO-1000 | 1000 | 380/6.0 | 1400*700*1640 | 1000/stainless steel/PE |
5 | ZYRO-1500 | 1500 | 380/7.0 | 1500*800*1800 | 1500/stainless steel/PE |
6 | ZYRO-2000 | 2000 | 380/8.0 | 1500*800*1800 | 2000/stainless steel/PE |
7 | ZYRO-3000 | 3000 | 380/9.5 | 1800*800*2000 | 3000/stainless steel/PE |
8 | ZYRO-5000 | 5000 | 380/11.5 | 1800*800*2000 | 5000/stainless steel/PE |
Note: 1. The RO membrane can't produce water when the temperature is lower than 0℃.
2. The machine needs to be changed double RO system or other better configuration if the TDS of feed water is more than 1000ppm.
* Operation: automatic control;
* Booster pump: provide pressure to multi-media filter and AC filter;
* Multi-media filter: get rid of turbidity, sediment, silt, rust, ago, colloid and part of organics;
* AC filter: adsorb residual chlorine, color, smell, harmful matter, organic matters;
* Softener resin: exchange Mg2+ and Ca2+ to Na+ to prevent scale;
* Cartridge filtration: filtrate microparticles whose accuracy is larger than 5um;
* High pressure pump: provide pressure to RO membrane;
* RO membrane: 0.0001-0.001um; remove more than 99% salt ions, organic matters, bacteria, virus, endotoxin, etc.
Optional configuration: EDI system, UF system, UV lamp, ozone generator, etc.