ZYRO water treatment system uses reverse osmosis technology with intellegent PLC touch
screen operation to purify water. The production RO water can used to chemical, medical,
commercial industry.
1.Total water inlet : ≥10m3/h, Raw water pressure:≥0.3MPA (If less than 0.3MPA,the raw water
tank and constant pressure system are needed)
2.Water yield : 5m3/h @25℃
3. Pure water quality: Condustivity ≤15µs/cm @25℃
4.Full automatic operation : The system realizes automatic operation by means of liquid level
interlocking, in which the pretreatment system is fully automatic (or manually operated)
Model | ZYRO-5000L | Water yield | 5m3/h @25℃ | |
Production model | Single reverse osmosis system | Operation | Full automatic | |
Inlet water pressure | ≥0.3Mpa | Raw water temperature | 5℃—45℃ | |
Total inlet water | ≥10m3/h | Inlet water pipe | DN32 | |
Inlet water index | City tap water , TDS≤500ppm | Desalination rate | ≥ 99% @25℃ | |
Water production index: conductivity ≤15µs/cm @25℃ | ||||
Operation pressure | 380V/220V—50Hz | Power | 1.2KW |
1. Raw water pump-- provide the pressure to quartz sand filter/active carbon filter.
2. Multi-medium filter-- get rid of sediment, suspended matter, organic matter, colloid, ect.
3. Active Carbon filter--remove the color, free chloride, organic matter, harmful matter, ect.
4. Antiscalant--exchange "ions" of calcium and magnesium with the most common and
easiest method.
5. Security filter--5um PP cotton filtrates microparticles.
6. High pressure pump-- Provide the high pressure to RO membrane ro.
7. RO membrane-- 0.0001-0.001um; remove more than 99% salt ions, organics, microorganism,
bacteria, etc.
No. | Model | Water Yield (L/H) | Voltage/ Power (V/Kw) | Body Size (L*W*H mm) | Water Tank (L/Material) |
1 | ZYRO-500 | 500 | 380/1.3 | 1400*700*1640 | 500/PE |
2 | ZYRO-1000 | 1000 | 380/1.4 | 1400*700*1640 | 1000/PE |
3 | ZYRO-1500 | 1500 | 380/1.95 | 1600*800*1600 | 1500/PE |
4 | ZYRO-2000 | 2000 | 380/3.15 | 1600*800*1600 | 2000/PE |
5 | ZYRO-3000 | 3000 | 380/5.6 | 1800*1000*1800 | 3000/PE |
6 | ZYRO-4000 | 4000 | 380/5.65 | 1800*1000*1800 | 4000/PE |
7 | ZYRO-5000 | 5000 | 380/9.15 | 1800*1000*2000 | 5000/PE |
1. Standard integrated appearance, compact structure saving floor space.
2.Standard blue glass steel pretreatment tank, beautiful appearance, higher cost of appearance.
3.Manual and automatic control in case of any emergency to facilitate the usage in emergency situations.
Higher cost of electronic control.
4, Electrical control with stainless steel 304 rack and shell, with a full closure plate shape, compared to the
semi-closed plate shape, higher cost.
5, The entire department uses ultra-pure water for ultra-clean PVC pipe fittings, low dissolution, prevent
the secondary pollution of pure water.
6. The electronic control device adopts one power and one control. Each electronic component has independent
layout and does not interfere with each other. The failure rate is lower, and the extended function wiring port is
reserved to facilitate the customer's new functions and use later.
7. The pre-treatment regeneration washing function is interconnected with the host electronic control to ensure
that the pre-treatment system is flushed and reproduced more fully, and the replacement frequency of consumables
is reduced, and the service life is longer.